ATEX tests sector

The ATEX sector provides regulatory support and perform laboratory tests in accordance with the harmonized standards for the Directive 2014/34 / EU of the series EN 60079 and EN 80079. It also carries out tests according to the IEC 60079 series of standards for the scheme IECEx

The chamber has an internal volume of about 4 m3 and can accommodate devices with dimensions up to 1000 x 1000 x 2000 mm with the possibility of powering the equipment under test with a voltage up to 800 V in three-phase and a maximum current of 100 A. The gas control and mixing system has been designed to create standard mixtures with oxygen and hydrogen, acetylene, ethylene, propane or methane. The accuracy of the mixtures is assured by comparing sample mixtures with the use of a gas chromatograph.

List of available tests - use the "Search" box to find standards.
Standard referenceTest description
ISO IEC EN 80079-36
Explosive atmospheres – Part 36: Non-electrical equipment for explosive atmospheres – Basic method and requirements
ISO IEC EN 80079-37
Non-electrical equipment for explosive atmospheres -- Non-electrical type of protection constructional safety ''c'', control of ignition sources ''b'', liquid immersion ''k''
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Resistance to impact
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Drop Test
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Degree of Protection (IP) by enclosure
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Temperature Tests
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Thermal shock test
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Capacitance measures
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Thermal Endurance tests
IEC 60079-0 ed 6 e 7
EN 60079-0 ed 2007 e 2012(A11)
Earth continuity
IEC 60079-1 ed 6 e 7
EN 60079-1 ed 2007 e 2014
Explosion tests
IEC 60079-1 ed 6 e 7
EN 60079-1 ed 2007 e 2014
Overpressure tests/sealing tests
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Degree of Protection (IP) by enclosure
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Dielectric strength
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Luminaires – impact and drop tests
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Rectification test
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Inoperative lamp test
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Abnormal operations of ballasts for discharge lamps
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Abnormal operation of luminaires with tubular fluorescent lamps
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
Test for wiring of luminaires subject to high-voltage impulses from ignitors
IEC 60079-7 ed 4 e 5
EN 60079-7 ed 2007 e 2015
General purpose connection and junction boxes
IEC
60079-7 ed 4 e 5
EN
60079-7 ed 2007 e 2015
Resistance heating devices and resistance heating units
IEC
60079-7 ed 4 e 5
EN
60079-7 ed 2007 e 2015
Terminal insulating material tests
IEC 60079-11 ed 6
EN 60079-11 ed 2012
Temperature tests
IEC 60079-11 ed 6
EN 60079-11 ed 2012
Dielectric strength tests
IEC 60079-11 ed 6
EN 60079-11 ed 2012
Mechanical tests (§10.6.1)
IEC 60079-11 ed 6
EN 60079-11 ed 2012
Mechanical tests (§10.6.2)
IEC 60079-11 ed 6
EN 60079-11 ed 2012
Cable pull test
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Temperatures
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Minimum degree of protection
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Clearances, creepage distances and separations - Comparative tracking index (CTI)
IEC 60079-15 ed 4 e 5
EN 60079-15 ed 2010
Electric strength
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Supplementary requirements for non-sparking luminaires - Thermal test (normal operation)
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Supplementary requirements for non-sparking luminaires - Thermal test (abnormal conditions)
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Supplementary requirements for non-sparking luminaires - Surface temperatures
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Supplementary requirements for non-sparking luminaires - Resistance to dust and moisture
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Insulation resistance and electric strength
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Thermal endurance to heat
IEC 60079-15 ed 4 e 5
EN 60079-15 ed 2010
Tests for enclosed break devices and non incendive components
IEC 60079-15 ed 4 e 5
EN 60079-15 ed 2010
Tests for sealed devices Conditioning
IEC 60079-15 ed 4 e 5
EN 60079-15 ed 2010
Tests for sealed devices
Voltage test
IEC 60079-15 ed 4 e 5
EN 60079-15 ed 2010
Tests for sealed devices
Leakeage test on sealed devices (method 1)
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Dielectric withstand test
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Test for sealed devices for luminaries (method A)
IEC 60079-15 ed 4 e 5
EN 60079-15 ed 2010
Type test requirements for restricted-breathing enclosures
IEC 60079-15 ed 4
EN 60079-15 ed 2010
Test for wiring of luminaires subject to high-voltage impulses from ignitors
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the compound - Water absorption test
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the compound - Dielectric strength test
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Maximum temperature
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Thermal endurance test
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Dielectric strength test
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Cable pull tes
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Pressure test for Group I and Group II electrical equipment
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Test for resettable thermal protective device
IEC 60079-18 ed 4
EN 60079-18 ed 2009 e 2015
Tests on the apparatus - Sealing test for built-in protective devices
IEC 60079-31 ed 2
EN 60079-31 ed 2014
Type tests for dust exclusion by enclosures
IEC 60079-31 ed 2
EN 60079-31 ed 2014
Thermal tests
IEC 60079-31 ed 2
EN 60079-31 ed 2014
Pressure test
CSA-C22.2
N° 60079-0
Explosive atmospheres
Part 0:Equipment – general use
CSA-C22.2
N° 60079-1
Explosive atmospheres Part 1:Equipment – protection by Flameproof Enclosures “d”
CSA-C22.2
N° 60079-15
Electrical apparatus for Explosive gas Atmospheres – Part 15: Construction, test and marking of type of Protection “n” Electrical apparatus
CSA-C22.2
N° 60079-18
Explosive atmospheres Part 18:Equipment – protection by encapsulation “m”
CSA-C22.2
N° 60079-31
Explosive atmospheres Part 31:Equipment – dust Ignition Protection by Enclosure “t”
CSA-C22.2
N° 60079-7
Explosive atmospheres Part 7:Equipment Protection by increased safety “e”
CSA-C22.2
N° 60079-11
Explosive Atmospheres – Part 11: Equipment protection by intrinsic safety “i”
CSA-C22.2
N° 30
Explosion-proof enclosures for Use in Class I Hazardous Locations
ISA-12.12.01/C
CSA-C22.2
N° 213
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous (classified) Location
UL 674
Electric Motors and Generators for Use in Division 1 hazardous (Classified) Locations
UL 1203
Explosion-proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Location
UL 60079-0
Explosive Atmosphers – Part 0:Equipment - General Requirements
UL 60079-1
Explosive Atmosphers – Part 1:Equipment protection by Flameproof Enclosures “d”
UL60079-11
Explosive Atmospheres – Part 11: Equipment protected by intrinsic safety “i”
UL 60079-15
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Tests and Marking of Type of protection “n” Electrical apparatus
UL 60079-18
Explosive atmospheres – Part 18: Equipment of protection by encapsulation “m”
UL 60079-31
Explosive atmospheres – Part 31: Equipment Dust ignition Protection by Enclosures “t”
UL 60079-7
Explosive atmospheres – Part 7: Equipment Protection by increased safety“e”